    COA vs Spec Sheet: What Each One Says

    Last updated:

    A specification sheet and a certificate of analysis look alike and answer different questions. A spec sheet says what a compound is meant to be. A certificate of analysis says what one lot measured.

    The specification sheet: the target

    A specification sheet, or spec sheet, lists the tests a compound is held to and the limit for each: purity at or above a figure, quantity within a range, endotoxins at or below an amount. It describes every lot the same way, because it is written before any lot is made.

    A spec sheet holds no results. It has no lot number, no test dates and no lab's signature. Words such as typical or target beside a value are the sign of one.

    The certificate of analysis: one lot's results

    A certificate of analysis, or COA, is a lab's report on a single lot. It names the lab and the lot, gives the dates, and lists each test with its method, its result and the limit the result was held to. Where a spec sheet says what should be true, a COA says what a lab found.

    How to Read a COA goes through a report line by line, and How to Verify a Lab Report shows how to confirm one with the lab.

    How the two fit together

    1. The spec sheet sets the limits, before a lot exists.
    2. The lot is made and sampled, and vials go to a lab.
    3. The COA shows what the lab found, each result beside its limit.
    4. The lot is released only if every result meets its limit. How a Lot Is Released covers that step.

    The limits on a COA are the spec sheet's limits, copied onto the report. That is why a COA can be read on its own: each line carries both the target and the result.

    The common mix-up

    The usual mix-up is a spec sheet shown where a COA belongs: a page of limits that reads like a page of results. A line such as purity, 98% or more, is a limit. A line such as purity, 98.7%, with a method, a lot number and a lab beside it, is a result. Both figures here are made up to show the difference.

    A spec sheet shown this way is not a false document. It is a true statement of what a seller aims for. It simply says nothing about any vial that was made.

    Telling them apart at a glance

    • A lot number and test dates: a COA has them. A spec sheet does not.
    • A results column beside a limits column: a COA. A single column of limits is a spec sheet.
    • A lab's name, a signature and a lookup code: a COA.
    • The words typical, target or specification, and no lab named: a spec sheet.
    • The same page for every batch: a spec sheet, whatever its title says.

    Other papers that come with an order

    • A certificate of conformance states that a lot meets its specification, without listing the results. It is a seller's or maker's statement, and it rests on a COA the reader has not seen.
    • A technical data sheet describes a compound in general: its formula, its mass, how to store it.
    • A packing slip lists what is in the box. A lot number on it ties each vial to its COA.

    When a page's kind is unclear, three questions sort it out. Does it name one lot? Does it show results? Does it name the lab that found them? Three yes answers make a COA.

    Why the difference matters

    A spec sheet is a promise, and a COA is the evidence that the promise was kept for one lot. A seller that shows only spec sheets has shown what it aims for. A seller that shows a COA for each lot, from a lab that confirms it, has shown what it shipped.

    What Third-Party Testing Means and the Research Peptide Supplier Checklist build on that difference.

    When limits change

    A seller can tighten or loosen a limit over time, and a careful one dates each version of its spec sheet. A COA is read against the limits printed on it, the ones in force when the lot was tested. A result that would miss today's limit and met the limit on its own report still passed, and the report shows which limit that was.

    Limits written down before the samples go out keep that record clean. A limit changed after the results come back, to fit them, is the thing a dated spec sheet guards against.

    Questions to ask about a document

    • Which lot does this page describe, if any?
    • Are these results, or limits?
    • Which lab produced the results, and does it confirm them?
    • Were the limits set before the lot was tested?

    The terms used here, from certificate of analysis to specification, are in the Lab Report Glossary.

    Our lots

    Every lot is tested by Vanguard Laboratory, an independent lab in Olympia, Washington, at its Elite level: identity, purity (HPLC), quantity, solubility, endotoxins, sterility (USP 71), heavy metals and a fentanyl screen. Every shipment comes with a testing card. Its lot code opens your lot's report on our Lot Reports page.

    How a Lot Is Released explains how each lot's limits and results fit together.