How to Read a Certificate of Analysis (COA)
Last updated:
A certificate of analysis, or COA, is a lab's report on one lot. It says who tested a sample, when, how, and what they found. Read in order, it answers three questions about a vial: Is it what the label says? Is all of it there? Is anything else in it?
Where each part sits on a report
Labs lay out their reports in their own ways, but the same parts show up on almost every one. The top names the lab and the report. The middle describes the sample. The bottom lists each test with its method, its result and the limit it was held to, then a signature, a date and often a code for checking the report with the lab.
| Test | Method | Result | Limit | Verdict |
|---|---|---|---|---|
| Identity | Mass spectrometry | Match | Match | Pass |
| Purity | HPLC | Share, % | Minimum, % | Pass |
| Endotoxins | USP 85 | EU/mg | Maximum | Pass |
- The lab's name and address.
- The report number, and the dates the sample arrived and the results came out.
- The sample: the compound, the amount on the label and the lot number.
- Each test with its method, its result, its limit and the verdict.
- Who approved the report, and the code for checking it with the lab.
Who tested it, and which lot
The top of a report names the lab, the report number, and the dates the sample arrived and the results came out. Under that, it describes the sample: the compound, the amount on the label and the lot number. Many reports also name the client who sent the sample in, which shows who ordered the test.
- The lab is a company of its own, apart from the seller and the maker. A report from the maker's own lab is the maker grading its own work. What Third-Party Testing Means covers the difference.
- The lot number on the report matches the lot number that came with the vial. A report covers one lot, so a report for another lot describes another batch.
- The report carries a date that fits the lot. One old report shown for every batch describes one batch only.
How a result line reads
Each test gets a line, or a small table of its own. A line usually holds five things:
- The test, such as purity or endotoxins.
- The method, such as high-pressure liquid chromatography, or a published US Pharmacopeia method such as USP 71.
- The result, as a number with its unit, or as pass or fail.
- The limit, also called the specification: the value the result has to meet.
- The verdict: pass or fail against that limit.
A limit gives a result its meaning. When a seller sets its limits in writing before the results come back, each line of the report answers a plain question: did this lot meet the bar?
Is it what the label says? Identity and purity
Identity confirms the molecule. Labs often weigh the molecule by mass spectrometry and compare the result with the known value for the compound on the label. A match means the vial holds the compound it names, so every other result on the report describes the right thing.
Purity, usually measured by high-pressure liquid chromatography (HPLC), is the share of the sample that is the target peptide. HPLC separates a sample into its parts and measures each one. Many reports show the result as a chart called a chromatogram: one tall peak for the target peptide and small peaks for leftovers from making it. The purity figure is the tall peak's share of the total.
Purity is a share, and quantity is an amount. A very pure vial can still hold less peptide than its label says, so a full report gives both. What an Identity Test Checks and What HPLC Purity Means go deeper on each, and How to Read a Chromatogram and How to Read a Mass Spectrum explain the two charts.
Is all of it there? Quantity and solubility
Quantity is the amount of peptide the lab measured in the vial, next to the amount on the label. The lab works it out by running a reference sample that holds a known amount and comparing the two results.
Solubility shows whether the powder dissolves fully in liquid. Powder that only partly dissolves leaves the liquid weaker than planned and full of clumps and specks. Quantity and Solubility on a Lab Report explains both results.
Is anything else in it? Endotoxins, sterility, heavy metals and fentanyl
- Endotoxins: bits of dead bacteria that cleaning steps can miss. The result is a number in endotoxin units per milligram (EU/mg), often from the US Pharmacopeia's test, USP 85. A lower number means less endotoxin. More on endotoxin testing.