For laboratory and research use only. Not for human consumption.

    What HPLC Purity Means

    Last updated:

    Purity is the number most reports lead with. It comes from high-pressure liquid chromatography, or HPLC, and it answers one question: of the material in the sample that the detector sees, how much is the compound on the label?

    How the method works

    A small amount of the sample is dissolved and pushed under high pressure through a narrow steel column packed with tiny coated beads. Each part of the sample clings to the beads a little differently, so the parts leave the column at different times. A detector at the end, usually reading ultraviolet light, records each part as it comes out.

    For peptides, labs most often use a reversed-phase column, whose beads carry an oily coating. The liquid that carries the sample starts out mostly water and shifts, minute by minute, toward a solvent such as acetonitrile. Parts that cling weakly to the coating leave early. Parts that cling tightly leave late, once the liquid is strong enough to pull them off. A little acid in both liquids keeps the peaks sharp.

    The detector reads light near 214 or 220 nanometers, where the bonds that link amino acids absorb it. Every peptide has those bonds, so the detector sees the target peptide and its close relatives alike. Some methods add a second reading near 280 nanometers, which picks up a few amino acids with ring-shaped side chains.

    Reading the chart

    The result is drawn as a chromatogram. Time runs along the bottom, and the detector's signal rises as a peak each time a part of the sample passes it.

    • Retention time: when a peak appears. A compound comes out at the same time on every run of the same method, which helps the lab spot it.
    • The main peak: the tall one, which should be the compound on the label.
    • Small peaks: leftovers from making the peptide, such as chains missing an amino acid or chains that picked up an extra oxygen.
    • Peak area: the space under each peak. More area means more of that part.
    • The baseline: the flat line between peaks. A steady baseline lets the software measure small peaks. A drifting or noisy one hides them.
    • A shoulder: a bump on the side of a peak, a sign that two parts left the column almost together.

    How to Read a Chromatogram goes through a chart and its peak table step by step.

    How the purity figure is worked out

    The lab adds up the area of every peak, then divides the main peak's area by that total. The method is called area percent. In a made-up run whose peaks total 1,000 units of area, a main peak holding 970 of them gives a purity figure of 97.0%.

    Software draws a line under each peak and measures the space above it. Where that line sits, and how small a peak has to be before the software leaves it out, both nudge the figure. A lab sets those rules in its written method, before the run.

    A good report states the method beside the result: the column, the wavelength, the run time and the liquids used.

    Why two labs can report different figures for one lot

    A purity figure belongs to its method. A longer run, or a slower shift from water to solvent, pulls apart peaks that a quick run leaves merged, so a more careful method can report a lower figure for the same vial. Columns from different makers separate the same mix in slightly different ways. The wavelength matters too, because some leftovers absorb more light than the target peptide and some absorb less.

    A small gap between two labs' figures for one lot is normal. A large gap is a reason to set the two methods side by side.

    What the small peaks are

    • Deletion sequences: chains missing one amino acid.
    • Truncated chains: chains that stopped growing early.
    • Oxidized forms: chains that picked up an extra oxygen, most often at an amino acid that holds sulfur.
    • Deamidated forms: chains in which one side chain has lost a nitrogen group, a slow change that water, heat and time bring on.
    • Mirror-image slips: chains in which one amino acid flipped to its mirror form while the chain was built.
    • Pairs and clumps: two or more chains stuck together.

    How Research Peptides Are Made explains where each comes from. Many of them are so close to the target peptide in size and makeup that they leave the column right beside it, which is why the main peak's neighbors get the closest look.

    What a purity figure leaves out

    Purity is a share of what the detector sees. Water, salts and counter-ions are not among the peaks counted, so they sit outside the figure. A powder can score very high on purity while a quarter of its weight is water and counter-ions. Peptide Purity vs Peptide Content sets the two numbers side by side.

    Two different molecules can also leave the column together and show up as one peak. A lab that feeds the column's output into a mass spectrometer can check what each peak holds.

    The other tests on a full report complete the picture:

    • Identity confirms that the main peak is the right molecule.
    • Quantity gives how much peptide sits in the vial, in milligrams.
    • Endotoxins, sterility and heavy metals check for kinds of contamination that call for their own methods.

    How a lab checks the method itself

    Before it runs samples, a lab checks the instrument with a known mix. The check is called system suitability. It confirms that peaks come out sharp, well apart and at the expected times. A blank run with no sample shows which bumps come from the liquids alone. Running a sample more than once shows how far the figure moves from run to run.

    The US Pharmacopeia's chapter on chromatography, USP 621, sets out these checks, and a method written to it names them.

    Questions to ask about a purity result

    • Which method produced the figure: the column, the liquids, the wavelength and the run time?
    • Is the chromatogram on the report, or only the number?
    • Was the main peak's identity confirmed by mass spectrometry?
    • Does the report also give quantity, in milligrams?
    • Which lot does the report name, and does the lab confirm it?

    How to Verify a Lab Report shows how to check a report with the lab. The terms used here are in the Lab Report Glossary.

    Our lots

    Every lot is tested by Vanguard Laboratory, an independent lab in Olympia, Washington, at its Elite level: identity, purity (HPLC), quantity, solubility, endotoxins, sterility (USP 71), heavy metals and a fentanyl screen. How a Lot Is Released covers what happens once the results are back, and Verified by Vanguard gives the case behind the purity test, and each of the others.