    What Heavy Metals Testing Checks

    Last updated:

    Heavy metals such as lead, mercury, arsenic and cadmium can carry over from the chemicals, water and machines used to make a peptide. A heavy metals test measures how much of each a sample holds.

    Where metals come from

    Metal can enter at many steps: catalysts and reagents used to make the peptide, steel equipment, containers, and the water used along the way. Tiny amounts turn up in many materials, which is why a test compares each result with a limit.

    • Reagents and catalysts: some steps in making a peptide use chemicals built around a metal, and the acids and solvents carry traces of their own.
    • Equipment: steel tanks, pipes and filling needles shed tiny amounts of iron, chromium and nickel.
    • Water: even purified water holds traces, and it touches every step.
    • Containers: glass vials and rubber stoppers can give up small amounts over time.

    How Research Peptides Are Made walks through the steps where each of these comes in.

    Which metals a panel lists

    Reports differ in how many metals they list. The four that matter most are lead, mercury, arsenic and cadmium. An international guideline on metal impurities, ICH Q3D, puts these four in its top class, because they do harm at low levels and serve no purpose in a finished product. Wider panels add metals that come from catalysts and equipment, such as palladium, nickel, chromium and copper.

    How ICP-MS measures them

    Most labs use inductively coupled plasma mass spectrometry, or ICP-MS. The lab breaks the sample down in acid, then sprays it into a plasma of argon gas hot enough to strip electrons from every atom. A mass spectrometer then counts the charged atoms by weight. Each metal has its own weight, so the instrument measures each one, down to tiny traces.

    Getting the sample ready is half the work. The lab seals it in a vessel with strong acid and heats it, often with microwaves, until nothing solid is left. Some metals, mercury above all, escape as vapor from an open vessel, so a closed one matters. The lab also adds a known amount of a rare element to every sample as a yardstick, which corrects for small drifts in the instrument.

    The instrument can be fooled when two things weigh the same. Argon from the plasma can pair with chlorine from the sample to form a particle that weighs the same as arsenic. Modern instruments pass the stream through a small cell of gas that removes such pairs before the count.

    ICP-MS is not the only instrument. A related one, ICP-OES, reads the light each metal gives off in the plasma. It is less sensitive, and still strong enough for many limits.

    The older test, and why reports changed

    For about a century the standard heavy metals test was a color test. The lab added a sulfur compound and judged how dark the mix turned against a lead standard. It gave one combined answer for several metals, missed some of them and depended on the eye. The US Pharmacopeia retired that test in 2018 in favor of instrument methods that measure each metal by name.

    A report with one line that reads only heavy metals, with no metals named, may still rest on the old approach.

    Reading a heavy metals result

    A report lists each metal with its result and its limit, often in micrograms per gram, which is the same as parts per million. A result shown as below a value means the metal sat under what the method can measure. The US Pharmacopeia's chapters on elemental impurities, USP 232 and USP 233, are a common reference for limits and methods.

    The units get small. A microgram per gram is one part per million, or ppm. A nanogram per gram is one part per billion, or ppb, a thousand times smaller. A result in ppb and a limit in ppm have to be put in the same unit before they can be compared.

    Three kinds of entry show up beside a metal's name:

    • Not detected: the metal was below the smallest amount the method can find.
    • Below the quantitation limit: the method saw a trace, too small to put a firm number on.
    • A number: a measured amount, to set against the limit.

    USP 233 also sets checks for the method itself, such as adding a known amount of each metal to a sample and confirming that the test finds it. What Not Detected Means on a Lab Report explains the limits behind these entries.

    Why limits differ from report to report

    There is no single limit for every use. The published limits were written for finished pharmaceutical products, and a seller of research reagents has to choose which ones it holds its lots to. What matters on a report is that each metal has a stated limit, that the limit was set before testing, and that the result sits under it.

    Accreditation and this test

    ISO/IEC 17025 is the international standard for the competence of testing laboratories. A lab is accredited for a published scope of tests, and an accredited lab can also run tests outside that scope.

    Vanguard Laboratory holds ISO/IEC 17025 accreditation from A2LA (certificate 6377.01, valid to September 30, 2027). Its accredited scope covers trace metals by ICP-MS, residual solvents, preservatives and some food microbiology. Of the tests on our lots, identity, purity (HPLC), quantity, solubility, endotoxins, sterility (USP 71) and the fentanyl screen are run by the same lab outside that scope. How to Verify a Lab Report shows how to read a lab's scope.

    Questions to ask about a heavy metals result

    • Does the report list each metal by name, with its own result and limit?
    • Which method was used: ICP-MS, or something else?
    • What is the smallest amount the method reports, and in what unit?
    • Were the limits set before testing?
    • Does the report name the lot on the vial?

    The terms used here, from detection limit to ICP-MS, are in the Lab Report Glossary.

    Our lots

    Every lot is tested by Vanguard Laboratory, an independent lab in Olympia, Washington, at its Elite level: identity, purity (HPLC), quantity, solubility, endotoxins, sterility (USP 71), heavy metals and a fentanyl screen. How a Lot Is Released covers what happens once the results are back, and the Heavy metals card on Verified by Vanguard gives the case behind this test.