What Not Detected Means on a Lab Report
Last updated:
Not detected does not mean zero. It means the test found nothing at or above the smallest amount it is able to find, so the result is only as strong as that amount is small.
Three limits every method has
- Detection limit, or LOD: the smallest amount the method can tell apart from nothing.
- Quantitation limit, or LOQ: the smallest amount the method can put a firm number on. It sits above the detection limit, often about three times higher.
- Reporting limit: the lowest value the lab will print on a report, set at or above the quantitation limit.
Between the first two is a gray zone. The method can see that something is there and cannot say how much.
How these results are written
- ND or not detected: nothing at or above the detection limit.
- A less-than sign and a value: less than that value, which is usually the reporting limit.
- BQL or BLQ: below the quantitation limit. A trace was seen, too small to measure.
- A number: a measured amount, to set against the limit for that test.
The first three all need a value beside them to mean anything. A bare ND, with no detection limit on the report, cannot be weighed.
Two kinds of limit on one line
A result line can carry two limits that are easy to mix up. One belongs to the method: the smallest amount it can find. The other belongs to the lot: the most the seller allows, also called the specification.
For a pass to mean much, the method's limit has to sit well under the lot's. In a made-up case, a metal is allowed up to 1 part per million. A method that can find 0.01 gives a not detected result real weight. A method that can only find 5 would report not detected for a lot holding four times the allowed amount.
Why a method's limit moves
- Dilution. If the lab dilutes a sample tenfold to run it, the smallest amount it can report in the powder rises tenfold.
- Sample size. A test on a larger portion of powder can find a smaller trace.
- The sample itself. A lot of peptide in the liquid can dampen the signal from a trace compound, so labs check their limits in the kind of sample they will test.
- The instrument. Two labs with different equipment report different limits for the same test.
That is why two reports on similar lots can both read not detected and still not be equal. The values beside the words say which screen was finer.
How a lab finds its limits
A lab does not take limits from an instrument's brochure. It measures them. It runs blanks, samples known to hold none of the compound, to learn how much the reading wanders with nothing there. It then runs samples with small known amounts added and finds the lowest one it can pick out every time.
A common rule of thumb compares the signal with the background noise: a signal about three times the noise can be detected, and one about ten times the noise can be measured. An international guideline on checking test methods, ICH Q2, describes these approaches.
Where this shows up on a peptide report
- Endotoxins: often a less-than sign and a value in EU per milligram. What Endotoxin Testing Checks explains the unit.
- Heavy metals: each metal reads not detected, below the quantitation limit, or a number. What Heavy Metals Testing Checks covers the units.
- The fentanyl screen: not detected, beside the method's detection limit. Why the Panel Includes a Fentanyl Screen explains why the limit belongs there.
- Purity: peaks smaller than a set size are left out of the sum, a reporting limit of its own. How to Read a Chromatogram shows where.
Sterility is the exception. Its result is growth or no growth, with no amount, and its strength comes from how many vials were tested. What Sterility Testing Checks explains.
Lower is not always the point
A method only has to be fine enough for the question. Once its limit sits well under the amount allowed, pushing it lower adds cost and little else. What a reader needs is the pair of values, the method's limit and the lot's, and a result on the right side of both.
Questions to ask about a not detected result
- What is the detection limit, and in what unit?
- What is the most the seller allows, and was it set before testing?
- Was the sample diluted, and does the limit on the report account for it?
- For a screen, which compounds did it look for?
The terms used here, from detection limit to quantitation limit, are in the Lab Report Glossary, and How to Read a COA shows where a limit sits on a result line.
Our lots
Every lot is tested by Vanguard Laboratory, an independent lab in Olympia, Washington, at its Elite level: identity, purity (HPLC), quantity, solubility, endotoxins, sterility (USP 71), heavy metals and a fentanyl screen. How a Lot Is Released covers what happens once the results are back, and Verified by Vanguard shows what each test looks for.